Explanation
Mismatched fabric World Wide Names (WWNs) were detected.
User Response
Complete the following steps:
- Run the lsportfc command to get the fabric World Wide Name (WWN) of each
port.
- List all partnered ports (that is, all ports for which the platform port ID is the same, and
the node is in the same I/O group) that have mismatched fabric WWNs.
- Verify that the listed ports are on the same fabric.
- Rewire if needed. For information about wiring requirements, see "Zoning requirements for
N_Port ID Virtualization" in your product documentation. After all ports are on the same fabric, the
event corrects itself.
- This error might be displayed by mistake. If you confirm that all remaining ports are on the
same fabric, despite apparent mismatches that remain, mark the event as fixed.