1245: Array storage is critically low on space

Explanation

When available space goes below a predetermined critical threshold, the error is displayed, along with the associated event code:

085081 Array storage is critically low on available physical space

The array is automatically write-protected when the error is displayed; no further data can be written to the array until the situation is corrected.

The exact value of the critical threshold is not user-configurable, and is subject to change.

User Response

Use the rmvdisk command to delete unwanted volumes.

Space is not immediately available after you remove a volume. To reclaim the space, run the recoverarray -trim command. This command might impact performance.

Note: Operating systems that do not have the unmap capability cannot delete data on a FlashSystem array.