1122: A high speed SAS adapter error has occurred.

Explanation

The high speed SAS adapter has detected a PCI bus error and requires service before it can be restarted. The high speed SAS adapter failure has caused all of the flash drives that were being accessed through this adapter to go Offline.

User Response

If this is the first time that this error has occurred on this node, complete the following steps:

  1. Power off the node.
  2. Reseat the high speed SAS adapter.
  3. Power on the node.
  4. Submit the lsmdisk task and ensure that all of the flash drive managed disks that are located in this node have a status of Online.

If the sequence of actions above has not resolved the problem or the error occurs again on the same node, complete the following steps:

  1. In the sequence shown, exchange the FRUs for new FRUs.
  2. Submit the lsmdisk task and ensure that all of the flash drive managed disks that are located in this node have a status of Online.
  3. Go to the repair verification MAP.

Possible Cause-FRUs or other:

  1. High speed SAS adapter (90%)
  2. System board (10%)