Explanation
For I/O groups that contain 8 GB node types, thin or compressed volumes cannot be created if the
FlashCopy bitmap is larger than 1.5 GB.
User Response
Complete one of the following actions:
- Upgrade the node types within the I/O group to contain more than 8 GB of memory.
- Remove data reduction volumes within the specified I/O group.
- Select another I/O group to create the thin or compressed volumes in a data reduction pool.
- Reduce the amount of FlashCopy bitmap memory that is in use for the I/O group to below 1.5
GB.
Then, retry the original command.