CMMVC8941E: Sessions cannot be added to the target controller due to conflict with existing connectivity or discovery output.

Explanation

One of the following situations occurred:
  • Discovery was run with one value for the iogroup parameter and the addiscsistorageport command was run with a different value for the iogroup parameter.
  • Discovery was run with a value for the iogroup parameter and the addiscsistorageport command was run cluster-wide (iogroup not specified).
  • Discovery was run cluster-wide and the addiscsistorageport command was run with a value for the iogroup parameter.
  • Sessions were already established through one I/O group, and the addiscsistorageport command was run to add connectivity through another I/O group or cluster-wide.
  • Sessions were already established cluster-wide, and the addiscsistorageport command was run to add connectivity through an I/O group.
  • Sessions were already established through a site, and the addiscsistorageport command was run to add connectivity through an I/O group or cluster-wide.
  • Sessions were already established through an I/O group or were established cluster-wide, and the addiscsistorageport command was run to add connectivity through a site. (You cannot mix I/O groups of different topologies in the same system.)

User Response

Run the management GUI or the addiscsistorageport command with the same site ID parameter that was used to run discovery with the detectiscsistorageportcandidate command.