Global settings apply across HDS Thunder, Hitachi AMS 200, AMS 500, and AMS 1000, WMS100, and HDS TagmaStore WMS systems.
HDS Thunder, Hitachi AMS 200, AMS 500, and AMS 1000, WMS100, and HDS TagmaStore WMS systems global settings supported by the system lists the global settings for these disk systems.
Option | Default setting | Required system setting |
---|---|---|
Start attribute | Dual active mode | Dual active mode |
SCSI ID/Port takeover mode | Not applicable | Not applicable |
Default controller | Not applicable | Not applicable |
Data-share mode | Used | Used |
Serial number | Same as the system default setting | |
Delay planned shutdown | 0 | 0 |
Drive detach mode | False | False |
Multipath controller (Thunder 9200 only) | False | False |
PROCOM mode | False | False |
Report status | False | False |
Multipath (Array unit) | False | False |
Turbu LU warning | False | False |
NX mode | False | False |
Auto reconstruction mode | False | False |
Forced write-through mode | False | False |
Changing logical unit mode 1 | False | False |
Multiple stream mode (Thunder 9200 only) | False | False |
Multiple stream mode (write) (Thunder 95xxV only) | False | False |
Multiple stream mode (read) (Thunder 95xxV only) | False | False |
RAID 3 mode (Thunder 9200 only) | False | False |
Target ID (9200 only) Mapping mode on 95xx | S-TID, M-LUN | M-TID, M-LUN (if sharing controller, otherwise S-TID, M-LUN) |
Data striping size | 16 K; 32 K; 64 K | Any (Thunder 9200); 64 K (Thunder 95xxV) |
Operation if processor failure occurs | Reset the fault | Reset the fault |
Command queuing | True | True |
ANSI Version | Not applicable | Not applicable |
Vendor ID | HITACHI | HITACHI |
Product ID (Thunder 9200) | DF500F | DF500F |
Product ID (Thunder 95xxV) | DF500F | DF600F |
ROM microprogram version | <Empty> | <Empty> |
RAM microprogram version | <Empty> | <Empty> |
Web title | <Empty> | Any setting supported |
Cache mode (Thunder 9200 only) | All off | All off |
Link separation (Thunder 9200 only) | False | False |
ROM Pseudo-response command processing (Thunder 9200 only) | Not applicable | Not applicable |
Save data pointer response (Thunder 9200 only) | Not applicable | Not applicable |
Controller identifier | False | False |
RS232C error information outflow mode | Off | Any |
Execute write and verify mode | True | True |