Ensure that you are familiar with the HSG80 controller container types for logical unit (LU) configuration.
HSG80 controller container types for LU configuration lists the valid container types.
Container | Number of Members | Maximum Size |
---|---|---|
JBOD - non transportable Attention: A
JBOD provides no redundancy at the physical disk-drive level.
A single disk failure can result in the loss of an entire storage pool and its associated volumes.
|
1 | Disk size minus metadata |
Mirrorset | 2 - 6 | Smallest member |
RAIDset | 3 - 14 | 1.024 terabytes |
Stripeset | 2 - 24 | 1.024 terabytes |
Striped Mirrorset | 2 - 48 | 1.024 terabytes |