561: Battery backplane or cabling fault

Explanation

Either the battery backplane has failed, or the power or LPC cables connecting the battery backplane to the rest of the system are not connected properly.

User Response

Follow troubleshooting procedures to fix the hardware:

  1. Check the cables connecting the battery backplane.
  2. Reseat the power and LPC cables.
  3. If reseating the cables does not fix the problem, replace the cables.
  4. Once the cables are well connected, but the problem persists, replace the battery backplane.
  5. Conduct the corrective service procedure described in 1108: Battery backplane cabling faulty or possible battery backplane requires replacing..