Explanation
The insufficient charge message can appear for various
reasons such as the battery is charging; the battery is missing or
has failed; there is a communication error, or there has been an over
temperature event.
User Response
This node error can be corrected by correcting each
of the underlying battery problems.
- If a battery is missing, replace the battery.
- If a battery is failed, replace the battery.
- If a battery is charging, this error should go away when the battery
is charged.
- If a battery is having a communication error (comm
errror), try to reseat the battery as described in the replacement
procedure. If reseating the battery does not correct the problem,
replace the battery.
- If a battery is too hot, the system can be started after it has
cooled.
Inspect the battery for damage after an over-temperature
event.
Possible Cause - FRUs or other:
If both
batteries have errors, battery charging might be underway. (No FRU)
If both batteries have errors that do not resolve after
a sufficient time to charge, battery charging might be impaired, such
as by a faulty battery backplane FRU.
Communication
errors are often correctable by reseating the battery or by allowing
the temperature of the battery to cool without the need to replace
the battery. (No FRU)
If a battery is missing or
failed, the solution is to replace the battery FRU.
Battery
(50%)
Other:
No FRU (50%)