On Xiotech ISE systems, logical units (LUs) are enumerated devices that have the same characteristics as logical unit numbers (LUNs).
An Xiotech ISE logical unit is referred to as a volume. Xiotech ISE volumes are enumerated devices that all share identical characteristics.
A single Xiotech ISE volume can potentially use the entire capacity that is allocated forthe systemstorage pools. However, it cannot exceed the 2 TB LUN size limit on the system. Any LUN that is 2 TB or larger is truncated to 2 TB, and a warning message is generated for each path to the LUN.
LUNs that are exported by Xiotech ISE systems are unique. They are created with a combination of serial numbers and counters along with a standard IEEE registered extended format.
Xiotech ISE LUNs are created and deleted by using either the Xiotech ISE Storage Management GUI or CLI. LUNs are formatted to all zeros at creation.
When a new LUN is created, the Xiotech ISE system begins a zeroing process in the background. If a read operation comes in to an area that is not processed yet, the system returns zeros as a read response. This behavior is the normal procedure. If a previous LUN with data was in that storage area, it is zeroed out. If a non-zeroed-out area gets read, the system returns zeros if it was not written to yet.
The Xiotech ISEstorage system does not use a special LUN. Storage can be presented by using any valid LUN, including 0.
ISE1 example: ISE1 WWNN: 20:00:00:14:c3:67:3f:c4 MRC1 WWPN: 20:00:00:14:c3:67:3f:c4 MRC2 WWPN: 20:00:00:14:c3:67:3f:c5
ISE2 example: ISE2 WWNN: 20:00:00:1F:93:10:31:78 MRC1 Port 1 WWPN: 20:00:00:1F:93:10:31:78 MRC1 Port 2 WWPN: 20:00:00:1F:93:10:31:79 MRC1 Port 3 WWPN: 20:00:00:1F:93:10:31:7A MRC1 Port 4 WWPN: 20:00:00:1F:93:10:31:7B MRC2 Port 5 WWPN: 20:00:00:1F:93:10:31:7C MRC2 Port 6 WWPN: 20:00:00:1F:93:10:31:7D MRC2 Port 7 WWPN: 20:00:00:1F:93:10:31:7E MRC2 Port 8 WWPN: 20:00:00:1F:93:10:31:7F
The Xiotech ISE system has no specific ownership of any LUN by any module. Because data is striped over all disks in a DataPac, performance is generally unaffected by the choice of a target port.
The Xiotech ISE system does not use LU grouping; all LUNs are independent entities.
No access ports are preferred for the Xiotech ISE system.
Ownership is not relevant to the Xiotech ISE system.