Target port characteristics can be set by using the set port command from the Symmetrix Command Line Interface (SYMCLI).
The target port characteristics can be viewed by using the symcfg command from the SYMCLI.
EMC Symmetrix and Symmetrix DMX port settings that can be used with the system lists the EMC Symmetrix and Symmetrix DMX port settings that can be used with thesystem.Option | EMC Symmetrix and Symmetrix DMX default setting | Required system setting |
---|---|---|
Disk_Array | Enabled | Disabled |
Volume_Set_Addressing | Enabled | Disabled |
Hard_Addressing | Enabled | Enabled |
Non_Participating | Disabled | Disabled |
Global_3rdParty_Logout | Enabled | Enabled |
Tagged_Commands | Enabled | Enabled |
Common_Serial_Number | - | Enabled |
Disable_Q_Reset_on_UA | Disabled | Disabled |
Return_busy_for_abort | Disabled | Disabled |
SCSI-3 | Disabled | Disabled or Enabled |
Environ_Set | Disabled | Disabled |
Unique_WWN | Enabled | Enabled |
Point_to_Point | Disabled | Enabled |
VCM_State | Disabled | Disabled or Enabled |
OpenVMS | Disabled | Disabled |
SPC-2 | Disabled | Disabled |