stopnode

Use the stopnode command to power off, reboot, or warmstart a node.

Syntax

 satask  stopnode    {  -poweroff   |  -reboot  |  -warmstart  }   [ panel_name ]

Parameters

-poweroff
(Required if -reboot and -warmstart are not specified) Powers off the node.
-reboot
(Required if -poweroff and -warmstart are not specified) Reboots the node.
-warmstart
(Required if -poweroff and -reboot are not specified) Restarts the I/O process and issues a diagnostic dump (also known as a full dump).
Important: You can also specify stopsystem -node -reset to restart the I/O process (but in a more controlled manner).
panel_name
(Optional) Identifies the node being serviced.
Note: If panel_name is not supplied, this applies to the node on which the command is running.

Description

Use the stopnode command to power off, reboot, or warmstart a node.

An example for powering off canister 1 in enclosure 2

satask stopnode -poweroff 02-1

The resulting output:

No feedback  

An example for rebooting a node

satask stopnode -reboot

The resulting output:

No feedback