Target port characteristics can be set by using the set port command from the Symmetrix Command-Line Interface (SYMCLI).
The target port characteristics can be viewed by using the symcfg command from the SYMCLI.
Recommended Director Bit Settings lists the options that must be used with the system. The system must be running Version 7.3 or later.
VMAX 10K, 20K, 40K | VMAX3 100K, 200K, 400K | Notes | |
---|---|---|---|
Director bit SCSI flags | |||
Negotiate_Reset(N) | Disabled | Disabled | |
Soft_Reset(S) | Disabled | Disabled | |
Environ_Set(E) | Disabled | Disabled | |
HP3000_Mode(B) | Disabled | Disabled | |
Common_Serial_Number(C) | Enabled | Enabled | |
Disable_Q_Reset_on_UA(D) | Disabled | Disabled | |
Sunapee(SCL) | Disabled | Disabled | |
Siemens(S) | Disabled | Disabled | |
Sequent(SEQ) | Disabled | Disabled | |
Avoid_Reset_Broadcast(ARB) | Disabled | Disabled | |
Server_On_AS400(A4S) | Disabled | Disabled | |
SCSI_3(SC3) | Enabled | Enabled | |
SPC2_Protocol_Version(SPC2) | Enabled | Enabled | |
SCSI_Support1(OS2007) | Enabled | Enabled | This director bit can be modified to comply with the required setting or desired setting if it is optional either on the target port basis or initiator basis. |
WP_Bypass(WPBP) | Disabled | Disabled | |
Director bit Fibre Channel flags | |||
Volume_Set_Addressing(V) | Disabled | Disabled | |
Non_Participating(NP) | Disable | Disabled | |
Init_Point_to_Point(PP) | Enabled | Enabled | |
Access_Logix(ACLX) | Enabled | Enabled | |
OpenVMS(OVMS) | Disabled | Disabled | |
AS400(AS4) | Disabled | Disabled | |
Auto_Negotiate(EAN) | Enabled | Enabled | |
VNX_Gateway_Direct_Attach | Disabled | Disabled | |
Show_ACLX_Device | N/A | Disabled | Do not enable this bit for system attachment. |