On the Hitachi TagmaStore AMS 2000 family of systems, port settings are configurable at the port level.
The settings that are listed in Hitachi TagmaStore AMS 2000 family of systems port settings supported by the system apply to storage systems that are in a switch zone that contains system nodes. If the system is shared between thesystem and another host, you can configure with different settings than shown if both of the following conditions are true:
No options are available with the scope of a single storage system.
Option | Default setting | Required system setting |
---|---|---|
Port settings | ||
Mapping mode | On | On |
Port type | Fibre | Fibre |
Reset LIP mode (signal) | Off | Off |
Reset LIP mode (process) | Off | Off |
LIP port all reset mode | Off | Off |
Host group list | ||
Host connection mode 1 | Windows | |
HostGroupName | "G000" | "G000" |
Middleware | Unsupported | Unsupported |
Host system configuration | ||
Platform | Windows | |
HostGroupName | "G000" | "G000" |
Middleware | Unsupported | Unsupported |
Host group information settings | ||
HostGroupNumber | 0 | 0 |
HostGroupName | "G000" | "G000" |
Host group options | ||
Host connection mode 1 | Standard mode | Standard mode |
Host connection mode 2 | Off | Off |
HP-UX mode | Off | Off |
PSUE read reject mode | Off | Off |
Mode parameters changed notification mode | Off | Off |
NACA mode (AIX only) | Off | Off |
Task management isolation mode | Off | Off |
Unique reserve mode 1 | Off | Off |
Port-ID conversion mode | Off | Off |
Tru cluster mode | Off | Off |
Product serial response mode | Off | Off |
Same node name mode | Off | Off |
CCHS mode | Off | Off |
Inquiry serial number conversion mode | Off | Off |
NOP-In suppress mode | Off | Off |
S-VOL disable advanced mode | Off | Off |
Discovery CHAP mode | Off | Off |