The battery charge within the enclosure is not sufficient for the node to safely become active in a cluster. The node will not start until sufficient charge exists to store the state and configuration data held in the node canister memory if power were to fail. Two batteries are within the enclosure, one in each of the power supplies. Only one of the batteries is charging, so the time to reach sufficient charge will be extended.
The node will start automatically when sufficient charge is available. The batteries do not have to be fully charged before the nodes can become active.
Both nodes within the enclosure share the battery charge, so both node canisters report this error.
The service assistant shows the estimated start time, and the battery status, in the node canister hardware details.