Explanation
Both batteries in the enclosure must be in a good
and charged state to maintain redundancy during the battery reconditioning
process. The selected battery cannot be reconditioned because the
other battery in the storage enclosure is not charged, not installed,
or it has an unresolved error condition.
User Response
Determine the condition of the other battery in the
storage enclosure and take appropriate action. For example, install
the battery if it is missing. If the battery has an error condition,
check the event log and follow the recommended Directed Maintenance
Procedure (DMP).