Explanation
This command requires that an MDisk is available
for array creation. There are no available MDisks for array creation
because the maximum number of MDisks is already configured on the
cluster.
User Response
Ensure that a local MDisk is available, and resubmit
the command. To make a local MDisk available for this task, either
delete an array on an existing local MDisk or remove a SAN attached
MDisk and configure a local MDisk.
Some other considerations to fix this error:
- Each distributed array occupies 16 slots, starting at an mdisk id
divisible by 16, therefore you might also consider the need to delete 16
unwanted mdisks starting on a mdiskid boundary divisible by 16.
If you need additional information see lsmdisk.
- Or, you can delete an unwanted distributed array to make space for a distributed array.
- You must also issue the detectmdisk command to ensure that the mdisk inventory is updated after deleting mdisks.