After you install the QLogic HBA and the device driver on hosts that run a Microsoft Windows Server operating system, you must configure the HBA.
For Lenovo Storage V3700 V2 and Lenovo Storage V3700 V2 XP: https://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v3700v2/6535
For Lenovo Storage V5030: https://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v5030/6536
Set the execution throttle to a suitable queue depth for your environment, for example, a value of 100. For more information about the execution throttle and queue depth, see http://support.qlogic.com/SupportCenter/articles/Question_Answers/2718.
If you are using subsystem device driver (SDD) 1.6 or later, set Enable Target Reset to No. See Table 1 to include the required parameters for the registry key.
Key | Required parameters |
---|---|
HKEY_LOCAL_MACHINE > SYSTEM > CurrentControlSet > Services > ql2xxx > Parameters > Device > DriverParameters | Buschange=0;FixupInquiry=1 Note: If you are using QLogic driver version 9.1.2.11 or later, Buschange cannot be set to zero. See your device driver
documentation for details.
|