You can modify a logical unit (LU) mapping by using the
command-line interface (CLI). The LUN ID and unique identifier (UID)
are linked and cannot be changed dynamically when the system is managing the MDisk.
To modify an LU mapping, complete the following steps:
- Migrate all of the data from the managed disk (MDisk):
- If the MDisk is in managed mode or image mode and the volume must be kept online, enter the following CLI command
and then proceed to step 2:
rmmdisk -mdisk MDisk number -force storage pool number
Note:
- The volume becomes a striped MDisk, not an
image-mode volume.
- All data that is stored on this MDisk is migrated to the other
MDisks in the storage pool.
- This CLI command can fail if sufficient free extents are not available
in the storage pool.
- If the MDisk is in image mode and you do not want to
convert the volume to a striped volume, stop all I/O to the image mode volume.
- Issue the following CLI command to
remove the host mapping and any SCSI reservation that the host has
on the volume:
rmvdiskhostmap -host host name virtual disk name
Note: If volume
protection is enabled and the volume that is being unmapped received
I/O within the defined volume protection interval, then the command
fails.
- Enter the following command to delete
the volume, where virtual disk name is the name of the volume that you want to delete.
rmvdisk virtual disk name
- Remove the LU mapping on the storage
system so that the LUN is not visible to the
system.
-
Important:
Issue the following CLI command to clear all error counters on
the MDisk:
includemdisk MDisk number
- Enter the following CLI command to
rescan the Fibre Channel network and detect that
the LU is no longer there.
The MDisk is no longer visible on the system.
- Enter the following CLI command to verify that the MDisk
is removed, where MDisk number is the number of
the MDisk that was removed.
lsmdisk MDisk number
If the MDisk is still displayed, repeat steps 3 and 4.
- Configure the mapping of the LU to the new LUN on the storage
system.
- Enter the following CLI command:
- Enter the following CLI command to check that the MDisk
now has the correct LUN:
The MDisk has the correct LUN.