Binding a logical unit (LU) to a RAID group can take a
significant amount of time on EMC CLARiiON systems.
Do not add the LU to a storage group until binding is
complete. If the LU is mapped to the
system during
the binding process, the LU might be identified with the wrong capacity.
If this occurs, run the following procedure to rediscover the LU with
the correct capacity:
- Unmap the LU from the system.
- Run detectmdisk and wait for the managed disk
to be unconfigured.
- Wait for any binding activity to complete.
- Remap the LU to the system.
- Run detectmdisk.