Complete the steps in the following procedures to debug iSCSI backend
sessions.
MDisks are in a degraded/offline state
- Run the command lseventlog to check the system event log. If the issue is
resolved by following the directed maintenance procedures (DMPs), then no further action is
required. If the issue is not resolved, complete the following steps to debug iSCSI sessions.
- Run the command lsmdiskmdisk_id | mdisk_name for the MDisk that is in degraded/offline state. In the
detailed view, note the values for the fields preferred_iscsi_port_id and
active_iscsi_port_id.
- Issue the svcinfo lsiscsistorageport command, map the values from step 2, and
verify the status field.
- If the status is not full, then obtain a detailed view for that particular session by using the
command svcinfo lsiscsistorageportsessions_row_id.
- In the detailed view of lsiscsistorageport from step 4, check the values of
the field connected. It indicates which nodes, which src_ip,
is having an issue. The src_port_id and node_id attributes are
also available in the detailed view.
- Using the command svcinfo lsportip, check the link status for the
src_port_id, node_id, and src_port_ip
tuple.
- If link status is not active, check the physical connection of the cable/small form-factor
pluggable (SFP) transceiver.
- Check the port status of the particular port on the switch.
Controllers are in a degraded/offline state
- Run the command lseventlog to check the system event log. If the issue is
resolved by following the directed maintenance procedures (DMPs), then no further action is
required. If the issue is not resolved, complete the following steps to debug iSCSI sessions.
- Run the command lscontrollercontroller_id | controller_name for the MDisk that is in degraded/offline
state. In the detailed view, note the values for the field iscsi_port_id.
- Issue the command svcinfo lsiscsistorageport, map the values from step 2, and
verify the status field.
- If the status is not full, then obtain a detailed view for that particular session by using the
command svcinfo lsiscsistorageportsessions_row_id.
- In the detailed view of lsiscsistorageport from step 4, check the values of
the field connected. It indicates which nodes, which src_ip,
is having an issue. The src_port_id and node_id attributes are
also available in the detailed view.
- Using the command svcinfo lsportip, check the link status for the
src_port_id, node_id, and src_port_ip
tuple.
- If link status is not active, check the physical connection of the cable/small form-factor
pluggable (SFP) transceiver.
- Check the port status of the particular port on the switch.