Configuring IBM® DS5000, IBM DS4000, and IBM DS3000 systems for the storage server

IBM® DS5000, IBM® DS4000™, and IBM® DS3000 storage systems are supported by the system.

The following steps provide the supported options and impact on the system:

  1. Set the host type for the system to IBM TS SAN VCE.
    For higher security, create a storage partition for every host that will have access to the storage system. If you set a default host group and add another host other than Lenovo Storage V series to the default group, the new host automatically has full read and write access to all LUNs on the storage system.
  2. See the following Web sites for the scripts that are available to change the setup of the IBM® DS5000, IBM® DS4000™, or IBM® DS3000 system:
The following limitations apply to partitions:
  • Only one IBM® DS5000, IBM® DS4000™, or IBM® DS3000 system storage partition that contains any of the ports of any of the nodes in a single system can be created.
  • Only map one partition to any of the ports on any of the nodes that are in the system to avoid unexpected behavior. For example, you can lose access to your storage or you might not receive warning messages, even if there are events logged in the system event log.
The following limitation applies to IBM® DS5000, IBM® DS4000™, or IBM® DS3000 Copy Services:
  • Do not use IBM® DS5000, IBM® DS4000™, or IBM® DS3000 Copy Services when the system is attached to an IBM® DS5000, IBM® DS4000™, or IBM® DS3000 system.
  • You can use partitioning to allow IBM® DS5000, IBM® DS4000™, or IBM® DS3000 Copy Services usage for other hosts.
The following information applies to the access LUN (also known as the Universal Transport Mechanism (UTM) LUN):
  • The access/UTM LUN is a special LUN that allows a IBM® DS5000, IBM® DS4000™, or IBM® DS3000 system to be configured through software over the Fibre Channel connection.
  • The access/UTM LUN does not have to be in the partition that contains the system ports because the access/UTM LUN is not required by the system. No events are generated if the access/UTM LUN is not in the partition.
  • If the access/UTM LUN is included in the system partition, the access/UTM LUN must not be configured as logical unit number 0. If the system partition (the host group) has been created with multiple hosts, the access LUN must be present in all hosts and must be the same logical unit number.
The following information applies to the logical unit (LU):
  • The system attempts to follow the preferred ownership that is specified by the storage system. You can specify which controller (A or B) is used for I/O operations to an LU.
  • If the system can see the ports of the preferred controller and event conditions do not exist, the Lenovo Storage V series system accesses the LU through one of the ports on the preferred controller.
  • If event conditions exist, the system ignores the preferred ownership of the IBM® DS5000, IBM® DS4000™, or IBM® DS3000 system.