541: Multiple, undetermined, hardware errors

Explanation

Multiple hardware failures were reported on the data paths within the node, and the threshold of the number of acceptable errors within a given time frame was reached. It was not possible to isolate the errors to a single component.

After this node error is raised, all ports on the node are deactivated. The node is considered unstable, and has the potential to corrupt data.

User Response

  1. Follow the procedure for collecting information for support, and contact your support organization.
  2. A software update may resolve the issue.
  3. Replace the node.