525: Unable to update system board service processor firmware.

Explanation

The node startup procedures have been unable to update the firmware for the Fibre Channel adapter. The update might take 90 minutes.

Explanation

The node startup procedures have been unable to update the firmware configuration of the node. The update might take 90 minutes.

Explanation

The node startup procedures have been unable to update the firmware configuration of the node canister.

User Response

  1. If the progress bar has been stopped for more than 90 minutes, power off and reboot the node. If the boot progress bar stops again on this code, replace the FRU shown.
  2. If the power off or restart does not work, try removing the power cords and then restarting.

User Response

  1. If the progress bar has been stopped for more than 90 minutes, power off and reboot the node. If the boot progress bar stops again on this code, contact your hardware manufacturer. The most likely source of the problem is the Fibre Channel adapter.
  2. If the power off or restart does not work, try removing the power cords and then restarting.

User Response

Follow troubleshooting procedures to fix the hardware:
  1. Follow the hardware remove and replace procedures for the node canister.
Possible Cause—FRUs or other:
  • Node canister (100%)

User Response

Follow troubleshooting procedures to fix the hardware:
  1. Remove the node from the system and abort the update on the management GUI.
  2. Follow the troubleshooting guide procedures to replace the node canister.
Possible Cause-FRUs or other: