CMMVC8708E: The command failed because the system does not have a hyperswap topology.

Explanation

An attempt was made to create a HyperSwap® volume on a system that does not have a HyperSwap® topology. The mkvolume command attempts to create a HyperSwap® volume in either of the following circumstances:
  • Two I/O groups are specified in the command
  • Two storage pools are specified within two independent sites that have a HyperSwap® topology. In this case the iogrp parameter can be omitted and the system will auto-select an I/O group.

User Response

Complete one of the following actions:
  • If you entered the command incorrectly, correct the command and retry.
  • Enter the mkvolume command with a single -iogrp parameter to create a basic volume.
  • Configure the system to use a HyperSwap® topology and retry the command.