Use the following worksheets to record configuration data that you need as you install a system.
One or two management addresses must be allocated for the system. The first management address is assigned for use on Ethernet port 1 of each node canister. If a second management address is allocated, then the system assigns this address for use on Ethernet port 2 of each node canister. The system assigns the management addresses to one node canister in the system at any time to provide access to system configuration and administration functions such as the management GUI. IPv4 and IPv6 protocols can be used.
Model | Port numbers | Description |
---|---|---|
Lenovo Storage V3700 V2 Lenovo Storage V3700 V2 XP |
1 | 1 GbE onboard used for configuration/management and iSCSI or IP replication. |
2/T | 1 GbE onboard functions as a technician port for initial setup,
and then can be used for configuration/management and iSCSI or IP
replication after cluster creation. Optionally, the technician port
function can be reenabled. Note: All other functions (management,
iSCSI, and so on) is disabled if the technician port is turned on.
|
|
3, 4, 5, 6 | Optional 1 or 10 GbE adapter ports that can be used only for iSCSI, FCoE, or IP replication. | |
Lenovo Storage V5030 | T | Technician access only. Not for configuration/management. |
1, 2 | 10 GbE onboard used for configuration/management and iSCSI or IP replication. | |
3, 4, 5, 6 | Optional 1 or 10 GbE adapter ports that can be used only for iSCSI, FCoE, or IP replication. |
A service address is also allocated to Ethernet port 1 of each node canister in the enclosure. The node canister retains the service IP address, providing convenient access to node canister configuration and service functions, such as the service assistant GUI and CLI for that node canister. IPv4 and IPv6 protocols can be used.
The management IP address is required when the system is initialized.
Use Table 2 to record the management IP addresses allocated for use by the system.
Configuration item | Value | Description |
---|---|---|
Port 1 | ||
Management IPv4 address | IPv4 address that is used for configuration and access to the system | |
Gateway IPv4 address | IPv4 address for the default local gateway for the system | |
IPv4 subnet mask | IPv4 subnet mask, which identifies the IPv4 network on which the system is operating | |
Management IPv6 address | IPv6 address that is used for configuration and access to the system | |
Gateway IPv6 address | IPv6 address for the default local gateway for the system | |
IPv6 prefix | The system prefix, which identifies the IPv6 network on which the system is operating | |
Port 2 (optional) | ||
Management IPv4 address | IPv4 address that is used for configuration and access to the system | |
Gateway IPv4 address | IPv4 address for the default local gateway for the system | |
IPv4 subnet mask | IPv4 subnet mask, which identifies the IPv4 network on which the system is operating | |
Management IPv6 address | IPv6 address that is used for configuration and access to the system | |
Gateway IPv6 address | IPv6 address for the default local gateway for the system | |
IPv6 prefix | The system prefix, which identifies the IPv6 network on which the system is operating |
Use Table 3 to plan the service addresses required to conduct service actions on individual node canisters.
Configuration item | Value |
---|---|
Control enclosure serial number: | |
Node canister 1 | |
Service IPv4 address | |
Gateway IPv4 address | |
IPv4 subnet mask | |
Service IPv6 address | |
Gateway IPv6 address | |
IPv6 prefix | |
Node canister 2 | |
Service IPv4 address | |
Gateway IPv4 address | |
IPv4 subnet mask | |
Service IPv6 address | |
Gateway IPv6 address | |
IPv6 prefix | |
Control enclosure serial number: | |
Node canister 1 | |
Service IPv4 address | |
Gateway IPv4 address | |
IPv4 subnet mask | |
Service IPv6 address | |
Gateway IPv6 address | |
IPv6 prefix | |
Node canister 2 | |
Service IPv4 address | |
Gateway IPv4 address | |
IPv4 subnet mask | |
Service IPv6 address | |
Gateway IPv6 address | |
IPv6 prefix |
Configuration item | Value |
---|---|
Language | |
Email server addresses | |
SNMP server addresses | |
SNMP community strings | |
Syslog servers |