Planning for configuration

Use the following worksheets to record configuration data that you need as you install a system.

Lenovo Storage V series enclosures

One or two management addresses must be allocated for the system. The first management address is assigned for use on Ethernet port 1 of each node canister. If a second management address is allocated, then the system assigns this address for use on Ethernet port 2 of each node canister. The system assigns the management addresses to one node canister in the system at any time to provide access to system configuration and administration functions such as the management GUI. IPv4 and IPv6 protocols can be used.

Table 1 lists the Lenovo Storage V series systems and the ports for each system.
Table 1. Lenovo Storage V series Ethernet ports
Model Port numbers Description
Lenovo Storage V3700 V2

Lenovo Storage V3700 V2 XP

1 1 GbE onboard used for configuration/management and iSCSI or IP replication.
2/T 1 GbE onboard functions as a technician port for initial setup, and then can be used for configuration/management and iSCSI or IP replication after cluster creation. Optionally, the technician port function can be reenabled.
Note: All other functions (management, iSCSI, and so on) is disabled if the technician port is turned on.
3, 4, 5, 6 Optional 1 or 10 GbE adapter ports that can be used only for iSCSI, FCoE, or IP replication.
Lenovo Storage V5030 T Technician access only. Not for configuration/management.
1, 2 10 GbE onboard used for configuration/management and iSCSI or IP replication.
3, 4, 5, 6 Optional 1 or 10 GbE adapter ports that can be used only for iSCSI, FCoE, or IP replication.

A service address is also allocated to Ethernet port 1 of each node canister in the enclosure. The node canister retains the service IP address, providing convenient access to node canister configuration and service functions, such as the service assistant GUI and CLI for that node canister. IPv4 and IPv6 protocols can be used.

Important: The management and service addresses for the system and its node canisters must be allocated within the same network.
In addition to the Ethernet ports used to connect and manage the system, the Ethernet port that is labeled T is the technician port.
Important: The technician port is not for connection to a switched network. When required, a personal computer is connected directly to the technician port for initialization and troubleshooting tasks.

The management IP address is required when the system is initialized.

Use Table 2 to record the management IP addresses allocated for use by the system.

Table 2. Management IP address configuration
Configuration item Value Description
Port 1
Management IPv4 address   IPv4 address that is used for configuration and access to the system
Gateway IPv4 address   IPv4 address for the default local gateway for the system
IPv4 subnet mask   IPv4 subnet mask, which identifies the IPv4 network on which the system is operating
Management IPv6 address   IPv6 address that is used for configuration and access to the system
Gateway IPv6 address   IPv6 address for the default local gateway for the system
IPv6 prefix   The system prefix, which identifies the IPv6 network on which the system is operating
Port 2 (optional)
Management IPv4 address   IPv4 address that is used for configuration and access to the system
Gateway IPv4 address   IPv4 address for the default local gateway for the system
IPv4 subnet mask   IPv4 subnet mask, which identifies the IPv4 network on which the system is operating
Management IPv6 address   IPv6 address that is used for configuration and access to the system
Gateway IPv6 address   IPv6 address for the default local gateway for the system
IPv6 prefix   The system prefix, which identifies the IPv6 network on which the system is operating

Use Table 3 to plan the service addresses required to conduct service actions on individual node canisters.

Table 3. Service IP address configuration
Configuration item Value
Control enclosure serial number:
Node canister 1
Service IPv4 address  
Gateway IPv4 address  
IPv4 subnet mask  
Service IPv6 address  
Gateway IPv6 address  
IPv6 prefix  
Node canister 2
Service IPv4 address  
Gateway IPv4 address  
IPv4 subnet mask  
Service IPv6 address  
Gateway IPv6 address  
IPv6 prefix  
 
Control enclosure serial number:
Node canister 1
Service IPv4 address  
Gateway IPv4 address  
IPv4 subnet mask  
Service IPv6 address  
Gateway IPv6 address  
IPv6 prefix  
Node canister 2
Service IPv4 address  
Gateway IPv4 address  
IPv4 subnet mask  
Service IPv6 address  
Gateway IPv6 address  
IPv6 prefix  
Use Table 4 to configure the system for event notification.
Table 4. Event notification settings
Configuration item Value
Language  
Email server addresses  
SNMP server addresses  
SNMP community strings  
Syslog servers