Target port characteristics can be set using the set port command from the Symmetrix Command Line Interface (SYMCLI).
The target port characteristics can be viewed using the symcfg command from the SYMCLI.
Table 1 lists the EMC Symmetrix and Symmetrix DMX port settings that can be used with the Lenovo Storage V seriesclustered system.Option | EMC Symmetrix and Symmetrix DMX default setting | Lenovo Storage V series required setting |
---|---|---|
Disk_Array | Enabled | Disabled |
Volume_Set_Addressing | Enabled | Disabled |
Hard_Addressing | Enabled | Enabled |
Non_Participating | Disabled | Disabled |
Global_3rdParty_Logout | Enabled | Enabled |
Tagged_Commands | Enabled | Enabled |
Common_Serial_Number | - | Enabled |
Disable_Q_Reset_on_UA | Disabled | Disabled |
Return_busy_for_abort | Disabled | Disabled |
SCSI-3 | Disabled | Disabled or Enabled |
Environ_Set | Disabled | Disabled |
Unique_WWN | Enabled | Enabled |
Point_to_Point | Disabled | Enabled |
VCM_State | Disabled | Disabled or Enabled |
OpenVMS | Disabled | Disabled |
SPC-2 | Disabled | Disabled |