Global settings apply across HDS Thunder, Hitachi AMS 200, AMS 500, and AMS 1000, WMS100, and HDS TagmaStore WMS systems.
Table 1 lists the global settings for these disk systems.
Option | Default setting | Lenovo Storage V series required setting |
---|---|---|
Start attribute | Dual active mode | Dual active mode |
SCSI ID/Port takeover mode | Not applicable | Not applicable |
Default controller | Not applicable | Not applicable |
Data-share mode | Used | Used |
Serial number | Same as the system default setting | |
Delay planned shutdown | 0 | 0 |
Drive detach mode | False | False |
Multipath controller (Thunder 9200 only) | False | False |
PROCOM mode | False | False |
Report status | False | False |
Multipath (Array unit) | False | False |
Turbu LU warning | False | False |
NX mode | False | False |
Auto reconstruction mode | False | False |
Forced write-through mode | False | False |
Changing logical unit mode 1 | False | False |
Multiple stream mode (Thunder 9200 only) | False | False |
Multiple stream mode (write) (Thunder 95xxV only) | False | False |
Multiple stream mode (read) (Thunder 95xxV only) | False | False |
RAID 3 mode (Thunder 9200 only) | False | False |
Target ID (9200 only) Mapping mode on 95xx | S-TID, M-LUN | M-TID, M-LUN (if sharing controller, otherwise S-TID, M-LUN) |
Data striping size | 16K; 32K; 64K | Any (Thunder 9200) |
Operation if processor failure occurs | Reset the fault | Reset the fault |
Command queuing | True | True |
ANSI Version | Not applicable | Not applicable |
Vendor ID | HITACHI | HITACHI |
Product ID (Thunder 9200) | DF500F | DF500F |
Product ID (Thunder 95xxV) | DF500F | DF600F |
ROM microprogram version | <Empty> | <Empty> |
RAM microprogram version | <Empty> | <Empty> |
Web title | <Empty> | Any setting supported |
Cache mode (Thunder 9200 only) | All off | All off |
Link separation (Thunder 9200 only) | False | False |
ROM Pseudo-response command processing (Thunder 9200 only) | Not applicable | Not applicable |
Save data pointer response (Thunder 9200 only) | Not applicable | Not applicable |
Controller identifier | False | False |
RS232C error information outflow mode | Off | Any |
Execute write and verify mode | True | True |