The lsnodecanister command returns a concise list or a detailed view of node canisters that are part of the clustered system (system).
lsnodecanister -filtervalue "name=md*"
Attribute | Value |
---|---|
status | Indicates the status. The values are:
|
config_node | Indicates if the node is a configuration node.
The values are:
|
IO_group_id | Indicates the I/O group of the node. |
IO_group_name | Indicates the name of the I/O group in the node. |
port_status | Indicates if the node is a configuration node.
The values are:
|
hardware | Indicates the node canister hardware type, for example 300. |
UPS_serial_number | Blank. |
UPS_unique_id | Blank. |
panel_name | Indicates a compound of the enclosure ID and the canister ID, separated with a hyphen. |
enclosure_id | Indicates the enclosure that the node is in. This field is blank for a node-based system. |
canister_id | Indicates the canister location within the enclosure. This field is blank for a node-based system. |
enclosure_serial_number | Indicates the serial number of the enclosure. This field is blank for a node-based system. |
service_IP_mode | Indicates the current mode of the service IPv4
|
service_IP_mode_6 | Indicates the current mode of the service IPv6
|
identify_LED | Indicates the node or node canister state - on, off, or blank. |
code_level | Indicates the current level of machine code running on the node canister. on, off, or blank. |
product_mtm | Indicates the product machine type. |
update_complete | Indicates if the node canister has completed its update. The values are yes or no. |
The first four Fibre Channel (FC) input/output (I/O) ports display the worldwide port name (WWPN), state, and speed. If there are less than four FC I/O ports, the fields display with a WWPN of 0000000000000000, port_status of inactive, and port_speed of N/A. To examine the FC ports, use the lsportfc command.
lsnodecanister -delim ,
id,name,UPS_serial_number,WWNN,status,IO_group_id,IO_group_name,config_node,UPS_unique_id,hardware,iscsi_name,iscsi_alias,panel_name,enclosure_id,canister_id,enclosure_serial_number,site_id,site_name 1,node114120,UPS_Fake_SN,5005076801005D00,online,0,io_grp0,yes,1000000000005D00,CG8,iqn.1986-03.com.ibm:2145.mycluster.node114120,,114120,,,,2,site2
lsnodecanister -delim , 1
id,1 name,hlcn114289 UPS_serial_number,10004BC018 WWNN,5005076801002978 status,online IO_group_id,0 IO_group_name,io_grp0 partner_nodecanister_id,2 partner_nodecanister_name,hlcn114253 config_nodecanister,no UPS_unique_id,20400001124C0048 port_id,5005076801402978 port_status,active port_speed,4Gb port_id,5005076801302978 port_status,active port_speed,4Gb port_id,5005076801102978 port_status,active port_speed,4Gb port_id,5005076801202978 port_status,active port_speed,4Gb hardware,300 iscsi_name,iqn.1986-03.com.ibm:2145.ldcluster-19.hlcn114289 iscsi_alias, failover_active,no failover_name,hlcn114253 failover_iscsi_name,iqn.1986-03.com.ibm:2145.ldcluster-19.hlcn114253 failover_iscsi_alias, panel_name,114289 enclosure_id, canister_id, enclosure_serial_number, service_IP_address,9.180.29.52 service_gateway,9.180.28.1 service_subnet_mask,255.255.254.0 service_IP_address_6, service_gateway_6, service_prefix_6, service_IP_mode,dhcp service_IP_mode, site_id,1 site_name,DataCenterA identify_LEDproduct_mtm 2145-CG8 code_level,7.4.0.0 (build 99.1.1406102000)