The MSA2000 System Storage Management Utility (SMU) provides configuration settings and options that can be used with Lenovo Storage V series clustered systems.
Table 1 describes the port settings that are supported by the Lenovo Storage V series.
Option | Values (any limits on the possible values) | Description |
---|---|---|
Host Port Configuration | 2 Gbps or 4 Gbps | Set according to the fabric speed. |
Internal Host Port Interconnect | Straight-through | Set to Straight-through for a point-to-point Fibre Channel connection. |
Host Port Configuration | Point-to-Point | Set to Point-to-point for use with Lenovo Storage V series. |
Option | Value | Description |
---|---|---|
Expose to All Hosts | Yes | After the mapping of the volume to the Lenovo Storage V series completes, this is modified to All other hosts (none no access). This can be done under the Assign Host Access Privileges frame. |
Automatically assign LUNs | Yes | This forces option expose to all hosts and is necessary for consistent LUN numbering. |
write-policy | write-back | |
optimization | any | |
read-ahead-size | default | |
independent | disable | This setting controls cache mirroring. Because Lenovo Storage V series requires mirroring, the independent=disable option must be used. |
There is no specific host option to present the MSA2000 systems to Lenovo Storage V series systems.Use a valid Microsoft Windows operating system as the host setting for Lenovo Storage V series.