Controller settings for HP MA and EMA

Controller settings apply across one HSG80 controller.

Table 1 describes the options that can be set by HSG80 controller command-line interface (CLI) commands for each HSG80 controller.

Table 1. HSG80 controller settings that are supported by the Lenovo Storage V series system
Option HSG80 controller default setting Lenovo Storage V series required setting
ALLOCATION_CLASS 0 Any value
CACHE_FLUSH_TIME 10 Any value
COMMMAND_CONSOLE_LUN Not defined Any value
CONNECTIONS_UNLOCKED

CONNECTIONS_
UNLOCKED

CONNECTIONS_
UNLOCKED

NOIDENTIFIER Not defined No identifier
MIRRORED_CACHE Not defined Mirrored
MULTIBUS_FAILOVER Not defined MULTIBUS_FAILOVER
NODE_ID Worldwide name as on the label Default
PROMPT None Any value
REMOTE_COPY Not defined Any value
SCSI_VERSION SCSI-2 SCSI-3
SMART_ERROR_EJECT Disabled Any value
TERMINAL_PARITY None Any value
TERMINAL_SPEED 9600 Any value
TIME Not defined Any value
UPS Not defined Any value