875: Request to cluster rejected.

Explanation

A candidate node canister could not be added to the clustered system. The node canister contains hardware or firmware that is not supported in the clustered system.

Data:

This node error and extra data is viewable through sainfo lsservicestatus on the candidate node only. The extra data lists a full set of feature codes that are required by the node canister to run in the clustered system.

User Response

  • Choose a different candidate that is compatible with the clustered system.
  • Update the clustered system to code that is supported by all components.
  • Do not add a candidate to the clustered system.
  • Where applicable, remove and replace the hardware that is preventing the candidate from joining the clustered system.

Possible Cause—FRUs or other cause.

For information on feature codes available, see the SAN Volume Controller and Storwize family Characteristic Interoperability Matrix on the support website: https://datacentersupport.lenovo.com/us/en/products/storage/lenovo-storage/v3700v2/6535.