750: Compression accelerator missing

Explanation

A compression adapter that was previously present was not detected.

User Response

  1. Use the svcinfo lsnodehw command to review the hardware on the node indicated by this event.
  2. If all missing and changed hardware is as expected, use the chnodehw command to accept the current node hardware configuration.
  3. Otherwise, complete each of the following steps in turn until the event automatically marks as fixed:
    1. Shut down the node. Ensure the correct hardware is installed in its correct location. Reseat any hardware that are indicated as missing. Bring the node back online. Go back to step 1.
    2. Shut down the node. Replace any hardware that is indicated as missing. Bring the node back online. Go back to step 1.
    3. Shut down the node. Replace the system board or canister. Bring the node back online. Go back to step 1.