Explanation
A CPU that was previously present has not been
detected. The CPU might not be correctly installed or it might have
failed.
User Response
- If possible, use the management GUI to run the recommended actions
for the associated service error code.
- Select one of the following actions:
- If removing the CPU was deliberate, follow the management GUI
recommended actions to mark the hardware change as intentional.
- If it is not possible to isolate the problem, use the remove and
replace procedures to replace the CPU.
- Replace the system board.