350: The 2145 cannot find a donor node.

Explanation

The 2145 cannot find a donor node.

User Response

If the progress bar has stopped for more than two minutes, perform the following steps:

  1. Ensure that all of the Fibre Channel cables are connected correctly and securely to the cluster.
  2. Ensure that at least one other node is operational, is connected to the same Fibre Channel network, and is a donor node candidate. A node is a donor node candidate if the version of software that is installed on that node supports the model type of the node that is being rescued.
  3. Ensure that the Fibre Channel zoning allows a connection between the node that is being rescued and the donor node candidate.
  4. Perform the problem determination procedures for the network.

Possible Cause-FRUs or other:

Other: