1625: Incorrect disk controller configuration.

Explanation

While running an MDisk discovery, the cluster has detected that a disk controller's configuration is not supported by the cluster. The disk controller might appear to be operating with the cluster; however, the configuration detected can potentially cause issues and should not be used. The unsupported configuration is shown in the event data.

User Response

  1. Use the event data to determine changes required on the disk controller and reconfigure the disk controller to use a supported configuration.
  2. Mark the error that you have just repaired as "fixed". If the problem has not been fixed it will be logged again by the managed disk discovery that automatically runs at this time; this could take a few minutes.
  3. Go to repair verification MAP.

Possible Cause-FRUs or other:

Other: