Explanation
Node canister location unknown.
User Response
Complete the following steps to resolve this problem.
- List all enclosure canisters for all control enclosures. Look
for an online canister that does not have a node ID associated with
it. This canister is the one with the problem.
- Unplug the SAS cable from port 2 of the canister that is identified
in step 1.
- Run the command lsenclosurecanister, and see
whether there is a node ID present. If step 2 fixes the error (a node
ID is present), then something failed in one of the attached devices.
- Reconnect the expansion enclosures and see whether the system
is able to isolate the fault.
- Reseat all the canisters on that strand and replace the canister
that is identified in step 1 if step 4 does not fix the error.
Possible Cause-FRUs or other:
- Nothing (80%)
- Canister (20%)