The replaceable server components for Lenovo Storage DX8200
For information about the terms of the warranty and getting service and assistance, see the Warranty Information document that comes with the server. For more information about getting service and assistance, see Getting help and technical assistance.
Visit the Lenovo ServerProven website for the latest options supporting plan.
The following illustration shows the major components in the server. The illustrations in this document might differ slightly from your hardware. For a list of structural parts and consumable parts, see Structural parts and consumable parts.
The following table lists the part numbers for Tier 1 and Tier 2 CRUs.
Index | Description | CRU part number (Tier 1) | CRU part number (Tier 2) |
---|---|---|---|
1 | 2.5-inch rear two hard-disk-drive kit | 00AL953 | |
2 | 3.5-inch rear two hard-disk-drive kit | 00AL954 | |
3 | PCIe Riser (2 x8 PCIe + 1 x8 ML2 Slots) | 00FK630 | |
3 | PCIe Riser (1 x16 PCIe + 1 x8 ML2 Slots) | 00FK631 | |
3 | PCIe Riser (1 x16 PCIe + 1 x8 PCIe ) | 00FK628 | |
3 | PCIe Riser (3 x8 PCIe ) | 00FK629 | |
4 | Heat sink, value | 00KA517 | |
4 | Heat sink, performance | 00KA518 | |
5 | Microprocessor, Intel Xeon Processor E5-2698 v4, 2.2 GHz, 50MB, Cache 2400 MHz, 135W (20-core) Addl Intel Xeon Processor E5-2698 v4, 2.2 GHz, 50MB, Cache 2400 MHz, 135W (20-core) | 00MW771 | |
5 | Microprocessor, Intel Xeon Processor E5-2695 v4, 2.1GHz, 45MB, Cache 2400MHz, 120W (18-core) Addl Intel Xeon Processor E5-2695 v4, 2.1GHz, 45MB, Cache 2400MHz, 120W (18-core) | 00MW772 | |
5 | Microprocessor, Intel Xeon Processor E5-2683 v4, 2.1GHz, 40MB, Cache 2400MHz, 120W (16-core) Addl Intel Xeon Processor E5-2683 v4, 2.1GHz, 40MB, Cache 2400MHz, 120W (16-core) | 00MW774 | |
5 | Microprocessor, Intel Xeon Processor E5-2667 v4, 3.2GHz, 25MB, Cache 2400MHz, 135W (8-core) Addl Intel Xeon Processor E5-2667 v4, 3.2GHz, 25MB, Cache 2400MHz, 135W (8-core) | 00MW776 | |
5 | Microprocessor, Intel Xeon Processor E5-2650L v4, 1.7GHz, 35MB, Cache 2400MHz, 65W (14-core) Addl Intel Xeon Processor E5-2650L v4, 1.7GHz, 35MB, Cache 2400MHz, 65W (14-core) | 00MW777 | |
5 | Microprocessor, Intel Xeon Processor E5-2643 v4, 3.4GHz, 20MB, Cache 2400MHz, 135W (6-core) Addl Intel Xeon Processor E5-2643 v4, 3.4GHz, 20MB, Cache 2400MHz, 135W (6-core) | 00MW778 | |
5 | Microprocessor, Intel Xeon Processor E5-2637 v4, 3.5GHz, 15MB, Cache 2400MHz, 135W (4-core) Addl Intel Xeon Processor E5-2637 v4, 3.5GHz, 15MB, Cache 2400MHz, 135W (4-core) | 00MW779 | |
5 | Microprocessor, Intel Xeon Processor E5-2630L v4, 1.8GHz, 25MB, Cache 2133MHz, 55W (10-core) Addl Intel Xeon Processor E5-2630L v4, 1.8GHz, 25MB, Cache 2133MHz, 55W (10-core) | 00MW780 | |
5 | Microprocessor, Intel Xeon Processor E5-2623 v4, 2.6GHz, 10MB, Cache 2133MHz, 85W (4-core) Addl Intel Xeon Processor E5-2623 v4, 2.6GHz, 10MB, Cache 2133MHz, 85W (4-core) | 00MW781 | |
5 | Microprocessor, Intel Xeon Processor E5-2609 v4, 1.7GHz, 20MB, Cache 1866MHz, 85W (8-core) | 00MW782 | |
5 | Microprocessor, Intel Xeon Processor E5-2603 v4, 1.7GHz, 15MB, Cache 1866MHz, 85W (6-core) | 00MW783 | |
5 | Microprocessor, Intel Xeon Processor E5-2699 v4, 2.2GHz, 55MB, Cache 2400MHz, 145W (22-core) Addl Intel Xeon Processor E5-2699 v4, 2.2GHz, 55MB, Cache 2400MHz, 145W (22-core) | 00YD967 | |
5 | Microprocessor, Intel Xeon Processor E5-2697 v4, 2.3GHz, 45MB, Cache 2400MHz, 145W (18-core) | 00YD968 | |
5 | Microprocessor, Intel Xeon Processor E5-2690 v4, 2.6GHz, 35MB, Cache 2400MHz, 135W (14-core) | 00YD969 | |
5 | Microprocessor, Intel Xeon Processor E5-2680 v4, 2.4GHz, 35MB, Cache 2400MHz, 120W (14-core) | 00YD970 | |
5 | Microprocessor, Intel Xeon Processor E5-2660 v4, 2.0GHz, 35MB, Cache 2400MHz, 105W (14-core) | 00YD971 | |
5 | Microprocessor, Intel Xeon Processor E5-2650 v4, 2.2GHz, 30MB, Cache 2400MHz, 105W (12-core) | 00YD972 | |
5 | Microprocessor, Intel Xeon Processor E5-2640 v4, 2.4GHz, 25MB, Cache 2133MHz, 90W (10-core) | 00YD973 | |
5 | Microprocessor, Intel Xeon Processor E5-2630 v4, 2.2GHz, 25MB, Cache 2133MHz, 85W (10-core) | 00YD974 | |
5 | Microprocessor, Intel Xeon Processor E5-2620 v4, 2.1GHz, 20MB, Cache 2133MHz, 85W (8-core) | 00YD975 | |
5 | Microprocessor, Intel Xeon Processor E5-2608L v4, 1.6GHz, 20MB, Cache 1866MHz, 50W (8-core) Addl Intel Xeon Processor E5-2608L v4, 1.6GHz, 20MB, Cache 1866MHz, 50W (8-core) | 00YE946 | |
5 | Microprocessor, Intel Xeon Processor E5-2618L v4, 2.2GHz, 25MB, Cache, 2133MHz, 75W (10-core) Addl Intel Xeon Processor E5-2618L v4, 2.2GHz, 25MB, Cache, 2133MHz, 75W (10-core) | 00YE947 | |
5 | Microprocessor, Intel Xeon Processor E5-2628L v4, 1.9GHz, 30MB, Cache 2133MHz, 75W (12-core) Addl Intel Xeon Processor E5-2628L v4, 1.9GHz, 30MB, Cache 2133MHz, 75W (12-core) | 00YE948 | |
5 | Microprocessor, Intel Xeon Processor E5-2648L v4, 1.8GHz, 35MB, Cache 2400MHz, 75W (14-core) Addl Intel Xeon Processor E5-2648L v4, 1.8GHz, 35MB, Cache 2400MHz, 75W (14-core) | 00YE949 | |
5 | Microprocessor, Intel Xeon Processor E5-2658 v4, 2.3GHz, 35MB, Cache 2400MHz, 105W (14-core) Addl Intel Xeon Processor E5-2658 v4, 2.3GHz, 35MB, Cache 2400MHz, 105W (14-core) | 00YE950 | |
6 | Memory module, 8GB TruDDR4 (1Rx4, 1.2V), PC4-19200 CL17 2400MHz LP RDIMM | 46W0823 | |
6 | Memory module, 8GB TruDDR4 (2Rx8, 1.2V), PC4-19200 CL17 2400MHz LP RDIMM | 46W0827 | |
6 | Memory module, 16GB TruDDR4 (2Rx4, 1.2V), PC4-19200 CL17 2400MHz LP RDIMM | 46W0831 | |
6 | Memory module, 32GB TruDDR4 (2Rx4, 1.2V), PC4-19200 CL17 2400MHz LP RDIMM | 46W0835 | |
6 | Memory module, 64GB TruDDR4 (4Rx4, 1.2V), PC4-17000 PC4 2400MHz LP LRDIMM | 46W0843 | |
7 | System board | 00MW385 | |
8 | 550W High Efficiency Platinum AC Power Supply | 94Y8137 | |
8 | 550W High Efficiency Platinum AC Power Supply | 94Y8139 | |
8 | 550W High Efficiency Platinum AC Power Supply | 94Y8173 | |
8 | 550W High Efficiency Platinum AC Power Supply | 00YL551 | |
8 | 550W High Efficiency Platinum AC Power Supply | 00YL553 | |
8 | 750W High Efficiency Platinum AC Power Supply | 94Y8142 | |
8 | 750W High Efficiency Platinum AC Power Supply | 94Y8144 | |
8 | 750W High Efficiency Platinum AC Power Supply | 00YL555 | |
8 | 750W High Efficiency Platinum AC Power Supply | 00YL557 | |
8 | 750W High Efficiency Titanium AC Power Supply | 00YL559 | |
8 | 750W High Efficiency Titanium AC Power Supply (200-240V) | 94Y8152 | |
8 | 750W High Efficiency Titanium AC Power Supply (200-240V) | 94Y8150 | |
8 | 750W High Efficiency Titanium AC Power Supply (200-240V) | 00YL561 | |
8 | 900W High Efficiency Platinum AC Power Supply | 94Y8146 | |
8 | 900W High Efficiency Platinum AC Power Supply | 94Y8148 | |
8 | 900W High Efficiency -48 V DC Power Supply | 94Y8167 | |
8 | 1300W High Efficiency Titanium AC Power Supply (200-240V) | 94Y8177 | |
8 | 1500W High Efficiency Platinum AC Power Supply | 94Y8181 | |
9 | Power supply filler panel | 94Y7610 | |
10 | Riser cage filler | 00AL950 | |
11 | Right functional EIA assembly | 00MV813 | |
12 | Right EIA blank | 00KF411 | |
13 | Left video EIA assembly | 00MV815 | |
14 | Front control panel assembly | 00YE420 | |
15 | Operator information panel assembly | 00KF492 | |
16 | Front USB assembly | 00YE411 | |
17 | LCD panel | 00D0464 | |
18 | 9.5 mm Ultra-Slim SATA DVD-ROM | 00FL352 | |
18 | 9.5 mm Ultra-Slim SATA multi-burner | 00FL353 | |
19 | Hard disk drive filler assembly, GEN 3 | 00FW856 | |
20 | Hard disk drive, 2.5-inch G3 simple-swap, near-line SATA, 7.2 K, 6 Gbps, 500 GB | 00NA602 | |
20 | Hard disk drive, 2.5-inch G3 simple-swap, near-line SATA, 7.2 K, 6 Gbps, 1 TB | 00NA627 | |
20 | Hard disk drive, 2.5-inch G3 simple-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 2 TB | 00NA537 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 300 GB | 00WG686 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 6 Gbps, 300 GB | 00AJ097 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 15 K, 12 Gbps, 300 GB | 00WG661 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 15 K, 6 Gbps, 300 GB | 00AJ082 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10K, 6 Gbps, 600 GB | 00AJ092 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 600 GB | 00WG691 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 15 K, 12 Gbps, 600 GB | 00WG666 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 15 K, 6 Gbps, 600 GB | 00AJ127 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 900 GB | 00WG696 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 6 Gbps, 900 GB | 00AJ072 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 1.2 TB | 00WG701 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 6 Gbps, 1.2 TB | 00AJ147 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SAS, 7.2 K, 6 Gbps, 500 GB | 00AJ122 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SAS, 7.2 K, 6 Gbps, 1 TB | 00AJ087 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 1 TB | 00NA492 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 2 TB | 00NA497 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 500 GB | 00AJ137 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 1 TB | 00AJ142 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 2 TB | 00NA527 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 15 K, 12 Gbps, 512e, 300 GB | 00NA222 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 600 GB | 00NA242 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 900 GB | 00NA252 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 1.2 TB | 00NA262 | |
20 | Hard disk drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 1.8 TB | 00NA272 | |
21 | 2.5-inch 4-drive filler panel | 00KF417 | |
22 | Hard disk drive, 3.5-inch G2 simple-swap, near-line SATA, 7.2 K, 6 Gbps, 500 GB | 81Y9803 | |
22 | Hard disk drive, 3.5-inch simple-swap, near-line SATA, 7.2 K, 6 Gbps, 1 TB | 81Y9807 | |
22 | Hard disk drive, 3.5-inch G2 simple-swap, near-line SATA, 7.2 K, 6 Gbps, 2 TB | 81Y9811 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, SAS, 15K, 12 Gbps, 300 GB | 00WG676 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, SAS, 15K, 12 Gbps, 600 GB | 00WG681 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 2 TB | 00FN114 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 4 TB | 00FN144 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 6 TB | 00FN174 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 512e, 2 TB | 00FN189 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 512e, 4 TB | 00FN209 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 512e, 6 TB | 00FN229 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2K, 6 Gbps, 4 TB | 49Y6003 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 6 Gbps, 1 TB | 90Y8568 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 6 Gbps, 2 TB | 90Y8573 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 6 Gbps, 3 TB | 90Y8578 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 12 Gbps, 1 TB | 00YL703 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 12 Gbps, 2 TB | 00YK001 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2K, 12 Gbps, 4 TB | 00YK006 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2K, 6 Gbps, 500 GB | 81Y9787 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 1 TB | 81Y9791 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 2 TB | 81Y9795 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 3 TB | 81Y9799 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SAS, 7.2 K, 12 Gbps, 512e, 8 TB | 00WH122 | |
23 | Hard disk drive, 3.5-inch G2 hot-swap, near-line SATA, 7.2 K, 6 Gbps, 512e, 8 TB | 00WH127 | |
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 12 Gbps, 200 GB | 00FN380 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 12 Gbps, 400 GB | 00FN390 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 12 Gbps, 800 GB | 00FN400 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 12 Gbps, 1.6 TB | 00FN410 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 200 GB | 00AJ208 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 400 GB | 00AJ213 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SAS, Enterprise, 800 GB | 00AJ218 | ||
Solid-state drive, 2.5-inch G3 hot-swap, SAS, Enterprise Mainstream, 12 Gbps, 400 GB | 00YC461 | ||
Solid-state drive, 2.5-inch G3 hot-swap, SAS, Enterprise Mainstream, 12 Gbps, 800 GB | 00YC466 | ||
Solid-state drive, 2.5-inch G3 hot-swap, SAS, Enterprise Mainstream, 12 Gbps, 1.6 TB | 00YC471 | ||
Solid-state drive, MLC G3 hot-swap, SAS, 6 Gbps, Enterprise Capacity, 3.84 TB | 00NA672 | ||
Solid-state drive, 2.5-inch G3 hot-swap, SATA, M500DC, Enterprise Mainstream Plus, 480 GB | 00NA689 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Enterprise Value, 120 GB | 00AJ396 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Enterprise Value, 240 GB | 00AJ401 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Enterprise Value, 480 GB | 00AJ406 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Enterprise Value, 800 GB | 00AJ411 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, S3700, 200 GB | 00AJ157 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, S3700, 400 GB | 00AJ162 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, S3700, 800 GB | 00AJ167 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Entry, 240 GB | 00FN338 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Entry, 480 GB | 00FN343 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Entry, 960 GB | 00FN348 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Value, S3500, 120 GB | 00AJ172 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Value, S3500, 240 GB | 00AJ177 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Value, S3500, 480 GB | 00AJ182 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Value, S3500, 800 GB | 00AJ187 | ||
Solid state drive, 2.5-inch MLC G3 hot-swap, SATA, Enterprise Value, S3500, 1.6 TB | 00FN279 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, S3510 series, 120 GB | 00WG621 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, S3510 series, 240 GB | 00WG626 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, S3510 series, 480 GB | 00WG631 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, S3510 series, 800 GB | 00WG636 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, 120 GB | 00YC386 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, 240 GB | 00YC391 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, 480 GB | 00YC396 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Entry, 960 GB | 00YC401 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Performance, S3710, 200 GB | 00YC321 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Performance, S3710, 400 GB | 00YC326 | ||
Solid state drive, 2.5-inch G3 hot-swap, SATA, Enterprise Performance, S3710, 800 GB | 00YC331 | ||
Solid state drive, 3.5-inch MLC hot-swap, SATA, Enterprise Value, 120 GB | 00AJ436 | ||
Solid state drive, 3.5-inch MLC hot-swap, SATA, Enterprise Value, 480 GB | 00AJ446 | ||
Solid state drive, 3.5-inch MLC hot-swap, SATA, Enterprise, S3700, 400 GB | 00AJ486 | ||
Solid state drive, 3.5-inch MLC hot-swap, SATA, Enterprise, S3700, 800 GB | 00AJ491 | ||
Solid state drive, 3.5-inch MLC hot-swap, SATA, Entry, 960 GB | 00FN363 | ||
Solid state drive, 3.5-inch hot-swap, SATA, Enterprise Entry, 960 GB | 00YC421 | ||
Solid state drive, 3.5-inch hot-swap, SATA, Enterprise Performance, S3710, 400 GB | 00YC341 | ||
Solid state drive, 3.5-inch hot-swap, SATA, Enterprise Performance, S3710, 800 GB | 00YC346 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 600 GB | 00NA292 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 512e, 1.2 TB | 00NA302 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 300 GB | 00WG706 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 600 GB | 00WG711 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 900 GB | 00WG716 | ||
Self-Encrypting drive, 2.5-inch G3 hot-swap, SAS, 10 K, 12 Gbps, 1.2 TB | 00WG721 | ||
PCIe solid-state drive, 2.5-inch G3 hot-swap, Enterprise Performance, NVMe, P3700, 400 GB | 00YA819 | ||
PCIe solid-state drive, 2.5-inch G3 hot-swap, Enterprise Performance, NVMe, P3700, 800 GB | 00YA822 | ||
PCIe solid-state drive, 2.5-inch G3 hot-swap, Enterprise Performance, NVMe, P3700, 1.6 TB | 00YA825 | ||
PCIe solid-state drive, 2.5-inch G3 hot-swap, Enterprise Performance, NVMe, P3700, 2.0 TB | 00YA828 | ||
PCIe solid state drive, 2.5-inch G3 hot-swap, Enterprise Value, NVMe, P3600, 400 GB | 90Y3228 | ||
PCIe solid state drive, 2.5-inch G3 hot-swap, Enterprise Value, NVMe, P3600, 800 GB | 90Y3231 | ||
PCIe solid state drive, 2.5-inch G3 hot-swap, Enterprise Value, NVMe, P3600, 1.6 TB | 90Y3234 | ||
PCIe solid state drive, 2.5-inch G3 hot-swap, Enterprise Value, NVMe, P3600, 2.0 TB | 90Y3237 | ||
24 | 3.5-inch hot-swap HDD filler panel | 69Y5364 | |
25 | 3.5-inch HDD simple-swap backplate (M5 to RAID) | 00KA479 | |
26 | 3.5-inch HDD hot-swap backplane with 8 HDDs | 00FJ751 | |
27 | 3.5-inch HDD hot-swap backplane with 12 HDDs | 00FJ754 | |
28 | 2.5-inch HDD hot-swap backplane | 00FJ756 | |
29 | 2.5-inch HDD hot-swap backplane (expander) | 00AG941 | |
30 | 2.5-inch HDD simple-swap backplate (M5 to RAID) | 00KA477 | |
32 | Fan | 00YE423 | |
33 | Air baffle | 00KF406 | |
34 | Power paddle module | 00FK636 | |
3.5-inch simple-swap filler | 69Y5368 | ||
Optical drive filler | 00KF416 | ||
Emulex 8Gb FC single-port HBA | 00JY847 | ||
Emulex 8Gb FC dual-port HBA | 00JY848 | ||
Emulex 16Gb FC single-port HBA | 00D8546 | ||
Emulex 16Gb FC single-port HBA | 01CV833 | ||
Emulex 16Gb FC dual-port HBA | 01CV843 | ||
Emulex 16Gb FC dual-port HBA | 00JY849 | ||
N2215 SAS/SATA HBA | 47C8676 | ||
N2225 SAS/SATA HBA | 00AE914 | ||
N2226 SAS/SATA HBA | 00KH483 | ||
M5225 SAS/SATA controller | 00AE939 | ||
ServeRAID M5210 SAS/SATA controller | 46C9111 | ||
ServeRAID M1215 SAS/SATA controller | 46C9115 | ||
QLogic 8Gb FC single-port HBA | 00Y5628 | ||
QLogic 8Gb FC dual-port HBA | 00Y5629 | ||
QLogic 16Gb FC single-port HBA | 00Y3340 | ||
QLogic 16Gb FC single-port HBA | 01CV753 | ||
QLogic 16Gb FC dual-port HBA | 00Y3344 | ||
QLogic 16Gb FC dual-port HBA | 01CV763 | ||
Solarflare SFN7122F 2x10GbE SFP+ Flareon Ultra | 47C9980 | ||
Broadcom NetXtreme I Quad Port GbE Adapter | 90Y9355 | ||
Broadcom NetXtreme I Dual Port GbE Adapter | 90Y9373 | ||
Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter | 94Y5182 | ||
Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ | 94Y5231 | ||
Broadcom NetXtreme II ML2 Dual Port 10GbaseT | 94Y5233 | ||
Intel Ethernet Dual Port Server Adapter I350-T2 | 00AG512 | ||
Intel Ethernet Quad Port Server Adapter I350-T4 | 00AG522 | ||
Intel I350-F1 1xGbE Fiber Adapter | 00AG502 | ||
Intel I350-T4 ML2 Quad Port GbE Adapter | 00JY932 | ||
Intel X520 Dual Port 10GbE SFP+ Adapter | 49Y7962 | ||
Intel X540-T2 Dual Port 10G BaseT Adapter | 49Y7972 | ||
Intel X540 ML2 Dual Port 10G baseT Adapter | 00JY912 | ||
Intel X550-T2 Dual Port 10GBase-T Adapter | 00MM862 | ||
Intel QLE7340 single-port 4X QDR IB x8 PCI-E 2.0 HCA | 59Y1890 | ||
Intel X710 2x10GbE SFP+ Adapter | 81Y3522 | ||
Intel X710 ML2 4x10GbE SFP+ Adapter | 94Y5203 | ||
Intel X710-DA2 ML2 2x10GbE SFP+ Adapter | 00JY942 | ||
Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA | 00WE025 | ||
Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA | 00WE029 | ||
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter | 94Y5195 | ||
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | 00AG563 | ||
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | 00AG573 | ||
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter and FCoE/iSCSi SW | 00AG583 | ||
Emulex VFA5 2x10 GbE SFP+ PCIe Adapter | 00JY823 | ||
Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW | 00JY833 | ||
Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter | 00D9552 | ||
Mellanox ConnectX-3 10 GbE Adapter | 00D9692 | ||
Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter | 00FP652 | ||
Mellanox ConnectX-3 EN Single-port SFP+ 10GbE Adapter | 00AE049 | ||
Mellanox Connect-IB FDR IB Single-port PCIe 3.0 x16 HCA | 00D1775 | ||
Mellanox Connect-IB FDR IB Single-port PCIe 3.0 x8 HCA | 00D1890 | ||
Mellanox QSFP to SFP+ Adapter | 00D9678 | ||
Mellanox ConnectX-4 EDR IB VPI Single-port x16 PCIe 3.0 HCA | 00KH926 | ||
Mellanox ConnectX-4 EDR IB VPI Dual-port x16 PCIe 3.0 HCA | 00KH930 | ||
Mellanox ConnectX-3 VPI Single-port QSFP FDR IB HCA | 00W0039 | ||
Mellanox Connect-IB Dual-port QSFP FDR IB PCI-E 3.0 x16 HCA | 46W0573 | ||
Mellanox ConnectX-3 EN Dual-port QSFP+ 40GbE Adapter | 95Y3461 | ||
Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter | 00MM953 | ||
Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter | 00MM963 | ||
MLX 25G ML2 Adapter | 00MN993 | ||
Chelsio T520-LL-CR Dual-port (SFP+) 10GbE PCI-E 3.0 Adapter | 46W0611 | ||
Chelsio T540-CR Quad-port (SFP+) 10GbE PCI-E 3.0 Adapter | 46W0617 | ||
Chelsio T580-LP-CR Dual-port (QSFP+) 40GbE PCI-E 3.0 Adapter | 46W0622 | ||
Broadcom NetXtreme 2x10GbE BaseT Adapter | 00E2714 | ||
Solarflare SFN5162F MR Dual Port 10GbE SFP+ Adapter | 47C9955 | ||
Brocade 10Gb SFP+ SR optical transceiver | 46C9297 | ||
Qlogic 10Gb SFP+ SR optical transceiver | 42C1816 | ||
QSFP+ 40GBASE-SR4 transceiver | 49Y7928 | ||
BNT SFP+ transceiver module assembly | 46C3449 | ||
ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade | 47C8657 | ||
ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade | 47C8661 | ||
ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade | 47C8665 | ||
ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade | 47C8669 | ||
Cable, Oculink, 830mm | 00MU995 | ||
Cable, UM KVM Module VGA+SD Dual RJ45 | 00AK143 | ||
Cable, COM PORT | 00KC965 | ||
Cable, FPC - PLANAR | 00FK803 | ||
Cable, SATA DVD for 2.5-inch models | 00FK809 | ||
Cable, SATA DVD for 3.5-inch models | 00FK853 | ||
Cable, SAS HD, 150 mm (vertical-vertical) | 00KF717 | ||
Cable, SAS HD, 250 mm | 00KF719 | ||
Cable, SAS HD, 350 mm (vertical-vertical) | 00KF704 | ||
Cable, SAS HD 250 mm | 00FK817 | ||
Cable, SAS HD 550 mm | 00FK811 | ||
Cable, SAS HD 750 mm | 00FK813 | ||
Cable, SAS HD 450/450 mm | 00FK845 | ||
Cable, SAS HD 590/580 mm | 00FK843 | ||
Cable, SAS HD 525/635 mm | 00FK839 | ||
Cable, SAS HD 770/835 mm | 00FK841 | ||
Cable, SAS HD 950/905 mm | 00FK847 | ||
Cable, SAS HD 950/905 mm, R/A | 00FK849 | ||
Cable, 0.6M HD mSAS to mSAS | 00D2142 | ||
Cable, 1.5M HD mSAS to mSAS | 00D2144 | ||
Cable, 3.0M HD mSAS to mSAS | 00D2148 | ||
Cable, 6.0m HD mSAS to mSAS | 44X3322 | ||
Cable, front HDD 80 mm | 00KC582 | ||
Cable, front HDD 150 mm | 00FK819 | ||
Cable, front HDD, 230 mm | 00FK825 | ||
Cable, front HDD, 260 mm | 00KF464 | ||
Cable, 3.5-inch front HDD, 16-pin | 00KA541 | ||
Cable, GPU power converter, 2x3, 240 mm | 00FK827 | ||
Cable, GPU power converter, 2x4, 240 mm | 00FK829 | ||
Cable, GPU power converter, 6P/8P 240 mm | 00FK831 | ||
Cable, USB conversion | 39M2909 | ||
Cable, external USB 3.0, 3 m | 00MW395 | ||
Cable, internal USB, 1 m | 44E8893 | ||
Cable, 425mm/925mm, super cap for ServRAID M5200 series flash | 46C9793 | ||
Cable, USB CRUs | 46M6475 | ||
Cable, GPU 6P/6P, 240mm | 00KG970 | ||
Cable, 6 Gbps external mini-SAS, SFF-8088 to SFF-8088, 1 m | 00YE299 | ||
Cable, 6 Gbps external mini-SAS, SFF-8088 to SFF-8088, 2 m | 00YE300 | ||
Cable, 6 Gbps external mini-SAS, SFF-8088 to SFF-8088, 4 m | 00YE301 | ||
Cable, 6 Gbps external mini-SAS, SFF-8088 to SFF-8088, 6 m | 00YE302 | ||
Cable, 6 Gbps external mini-SAS, SFF-8644 to SFF-8088, 0.5 m | 00YE303 | ||
Cable, 7 Gbps external mini-SAS, SFF-8644 to SFF-8088, 1 m | 00YE304 | ||
Cable, 8 Gbps external mini-SAS, SFF-8644 to SFF-8088, 2 m | 00YE305 | ||
Cable, 9 Gbps external mini-SAS, SFF-8644 to SFF-8088, 4 m | 00YE306 | ||
Cable, 10 Gbps external mini-SAS, SFF-8644 to SFF-8088, 6 m | 00YE307 | ||
Cable, 0.5m Intel OPA 100 Series Passive Copper QSFP28 | 00WE033 | ||
Cable, 0.75m Intel OPA Passive Copper QSFP28 | 00WE037 | ||
Cable, 1m Intel OPA 100 Series Passive Copper QSFP28 | 00WE041 | ||
Cable, 1.25m Intel OPA 100 Series Passive Copper QSFP28 | 00WE045 | ||
Cable, 1.5m Intel OPA 100 Series Passive Copper QSFP28 | 00WE049 | ||
Cable, 2m Intel OPA 100 Series Passive Copper QSFP28 | 00WE053 | ||
Cable, 3m Intel OPA 100 Series Passive Copper QSFP28 | 00WE057 | ||
Cable, 5m Intel OPA 100 Series Active Optical QSFP28 | 00WE061 | ||
Cable, 10m Intel OPA 100 Series Active Optical QSFP28 | 00WE065 | ||
Cable, 15m Intel OPA 100 Series Active Optical QSFP28 | 00WE069 | ||
Cable, 20m Intel OPA 100 Series Active Optical QSFP28 | 00WE073 | ||
Line cord, 2.8 m, 10A/100-250V, C13 to IEC 320-C14 rack power cable | 39M5377 | ||
Line cord, 2.8 m, 13A/125-10A/250V, C13 to IEC 320-C14 rack power cable | 39M5509 | ||
ServeRAID M5100/M5200 Series flash power module | 00JY023 | ||
32 GB Enterprise Value USB Memory Key | 00ML201 | ||
2 GB USB Memory Key | 42D0545 | ||
4 GB USB Memory Key | 00WH143 | ||
3.0-volt battery | 33F8354 | ||
RDX 3.0 internal tape drive | 00MW717 | ||
RDX 3.0 external tape drive | 00MW718 | ||
NVIDIA Grid K1 (actively cooled) | 90Y2432 | ||
NVIDIA Grid K2 (actively cooled) | 90Y2395 | ||
NVIDIA Tesla K40c | 90Y2408 | ||
NVIDIA Tesla M60 GPU, PCIe (active) | 90Y2472 | ||
NVIDIA Quadro M5000 GPU, PCIe (active) | 90Y2488 | ||
Security bezel | 00FK615 | ||
MISC KIT | 00KF419 | ||
Slim slide kit | 00KA592 | ||
Slide Gritstone | 00MV990 | ||
Cable management arm (CMA) | 00KA594 | ||
Label, chassis | 00KF412 | ||
Labels, system service and FRU/CRU (2.5-inch) | 00YE416 | ||
Labels, system service and FRU/CRU (3.5-inch) | 00YE417 | ||
Gen-II Universal slides kit | 00KA593 | ||
Air baffle (ML2) | 00KG754 | ||
Intel Xeon Phi 3120A | 90Y2403 | ||
Intel Xeon Phi 7120A | 90Y2420 | ||
Flash Adapter, Enterprise Mainstream, io3, 1.25 TB | 00YA801 | ||
Flash Adapter, Enterprise Mainstream, io3, 1.6 TB | 00YA804 | ||
Flash Adapter, Enterprise Mainstream, io3, 3.2 TB | 00YA807 | ||
Flash Adapter, Enterprise Mainstream, io3, 6.4 TB | 00YA810 | ||
Flash Adapter, Enterprise Performance, NVMe, P3700, 1.6 TB | 00YA813 | ||
Flash Adapter, Enterprise Performance, NVMe, P3700, 2 TB | 00YA816 | ||
Flash Adapter, Enterprise Value, io3, 1250 GB | 00AE985 | ||
Flash Adapter, Enterprise Value, io3, 1600 GB | 00AE988 | ||
Flash Adapter, Enterprise Value, io3, 3200 GB | 00AE991 | ||
Flash Adapter, Enterprise Value, io3, 6400 GB | 00AE994 | ||
Flash Adapter, Enterprise, io3, 1000 GB | 00AE997 | ||
Flash Adapter, Enterprise, io3, 1300 GB | 00JY000 | ||
Flash Adapter, Enterprise, io3, 2600 GB | 00JY003 | ||
Flash Adapter, Enterprise, io3, 5200 GB | 00JY006 | ||
Video adapter, NVIDIA Quadro K420 | 90Y2436 | ||
Video adapter, NVIDIA Quadro K620 | 90Y2440 | ||
Video adapter, NVIDIA Quadro K2200 | 90Y2444 | ||
Video adapter, NVIDIA Quadro K4200 | 90Y2448 | ||
Video adapter, NVIDIA Quadro K5200 | 90Y2452 | ||
Video adapter, NVIDIA Quadro K6000 | 90Y2371 | ||
Video adapter, NVIDIA Telsa K8 (actively cooled) | 90Y2456 | ||
SD Media Adapter | 00YK624 | ||
SD flash memory card | 00ML701 | ||
NVMe PCIe SSD Extender Adapter | 47C8304 | ||
NVMe Backplane | 47C8333 | ||
EIA Nameplate | 00MV897 | ||
DPI Universal 7 C13 PDU | 39Y8914 | ||
Media cage bay with bezel (without LCD panel, front USB assembly, and operator information panel assembly) | 00YE410 | ||
Media cage bay without bezel (with front USB assembly and operator information panel assembly) | 00YJ759 | ||
Professional keyboard, USB, US English, 103P, RoHS v2 | 00AL883 | ||
Optical wheel mouse, USB, black | 00MW370 | ||
Mounting screws, M3x3, RoHS | 42C3933 | ||
Alcohol wipe | 59P4739/ 00MP352 |