S.51009 : No system memory has been detected. No Memory Detected

No system memory has been detected. No Memory Detected

Severity

Error

User Response

Complete the following steps:
  1. If any memory errors are logged other than this one, take actions indicated for those codes first.
  2. If no other memory diagnostic codes appear in the logs, verify that all DIMM connectors are enabled using the Setup utility or the ToolsCenter Suite CLI.
  3. If the problem remains, shut down and remove node from chassis and physically verify that one or more DIMMs are installed and that all DIMMs are installed in the correct population sequence.
  4. If DIMMs are present and properly installed, check for any lit DIMM-connector LEDs, and if found, reseat those DIMMs.
  5. Reinstall node in chassis, power on node, then check logs for memory diagnostic codes.
  6. (Trained technician only) If the problem remains, replace the processor.
  7. (Trained technician only) If the problem remains, replace the system board.