[ProcessorElementName] has Failed with FRB1/BIST condition. (All CPUs)
This message is for the use case when an implementation has detected a
Processor Failed - FRB1/BIST condition.
May also be shown as
806f02072584ffff or 0x806f02072584ffff
Alert Category
Critical - CPU
CIM Information
Prefix:PLAT
and ID:0044
Automatically Notify Support
Yes
User Response
- Make sure that the latest levels of firmware and device drivers are installed for all adapters and
standard devices, such as Ethernet, SCSI, and SAS.
Important: Some cluster solutions require specific code levels or coordinated code updates. If the
device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
- Update the firmware (UEFI and IMM) to the latest level (Updating the firmware).
- Run the DSA program.
- Reseat the adapter.
- Replace the adapter.
- (Trained technician only) Replace microprocessor n.
- (Trained technician only) Replace the system board. (n = microprocessor number)
One of the CPUs :