Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. (Internal RAID)
This message is for the use case when an implementation has detected a
Fault in a slot.
May also be shown as
806f00213001ffff or 0x806f00213001ffff
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0330
Automatically Notify Support
Yes
User Response
- Check the PCI LED.
- Reseat the affected adapters and riser card.
- Update the server firmware (UEFI and IMM) and adapter firmware.
Important: Some cluster solutions require specific code levels or coordinated code updates.
If the device is part of a cluster solution, verify that the latest level of code is supported for
the cluster solution before you update the code.
- Replace the affected adapters.
- Replace the riser card.
- (Trained service technicians only) Replace the system board.
PCI 1 :
PCI 2 :
PCI 3 :
PCI 4 :
PCI 5 :
PCI 6 :
PCI 7 :
PCI 8 :