Non-redundant:Insufficient Resources for
[RedundancySetElementName] has asserted. (Power Resource)
This message is for the use case when a Redundancy
Set has transitioned to Non-redundant:Insufficient Resources.
May also be shown as
800b05091301ffff or 0x800b05091301ffff
Alert Category
Critical - Redundant Power Supply
CIM Information
Prefix:PLAT
and ID:0810
Automatically Notify Support
No
User Response
- Power load may be handled by remaining power supply. The system will attempt to throttle to
avoid a power supply over-current condition. But a system shutdown may happen anyway if the power
load is too great.
- Reduce the total power consumption by removing newly added or unused options like drives or adaptors.
- Use the Lenovo Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
- Replace the power supply with higher rated power if Oversubscription_Fault seen in power supply.
- Please reseat power cords and power supplies.