Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. (RAID Vol State)
This message is for the use case when an implementation has detected a
Sensor transitioned to non-recoverable from less severe.
May also be shown as
8007030d2582ffff or 0x8007030d2582ffff
Alert Category
Critical - Other
CIM Information
Prefix:PLAT
and ID:0524
Automatically Notify Support
No
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components:
a. Hard disk drive (wait 1 minute or more before reinstalling the drive)
b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time:
a. Hard disk drive
b. Cable from the system board to the backplane
c. Hard disk drive backplane (n = hard disk drive number)