Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2 OverTemp)
This message is for the use case when an implementation has detected a
Sensor transitioned to critical from less severe.
May also be shown as
800702010302ffff or 0x800702010302ffff
Alert Category
Critical - Temperature
CIM Information
Prefix:PLAT
and ID:0522
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow (front
and rear of the server), that the air baffles are in place and correctly installed, and that
the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications
(see Features and specifications for more information).
- Make sure that the heat sink for microprocessor n is installed correctly.
- (Trained technician only) Replace microprocessor n. (n = microprocessor number)