Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (Rear BP2 Temp)
This message is for the use case when an implementation has detected an
Upper Critical sensor going high has asserted.
May also be shown as
800109010708ffff or 0x800109010708ffff
Alert Category
Critical - Temperature
CIM Information
Prefix:PLAT
and ID:0494
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
- Check fan cable on rear HDD cable is connected correctly.
- Check the fans on rear HDD cage are functional.
- Replace rear HDD drive cage.