Skip to main content

Replacing the operator information panel assembly

Use the information to replace the operator information panel assembly.

To install the operator information panel, complete the following steps.

  1. Read the safety information that begins in Safety and Installation guidelines.
  2. From the front of the server, slide the operator information panel into the server until it stops.
    Figure 1. Operator information panel assembly installation
    Operator information panel assembly installation
  3. Connect the signal cable to the rear of the operator information panel; then, connect the other end of the signal cable to the connectors on the system board. Route the signal cable as shown in the following illustration. Secure the cable with any cable clips on the chassis.
    Figure 2. Signal cable installation
    Signal cable installation
  4. Remove the air baffle (see Removing the air baffle).
  5. Inside the server, connect the cable to the rear of the operator information panel assembly.
  6. Reinstall the air baffle (see Replacing the air baffle).
  7. Install the cover (see Replacing the server top cover).
  8. Reconnect the power cords and any cables that you removed.
  9. Turn on the peripheral devices and the server.