Skip to main content

Power-on password

If a power-on password is set, when you turn on the server, you must type the power-on password to complete the system startup. You can use any combination of 6 - 20 printable ASCII characters for the password.

When a power-on password is set, you can enable the Unattended Start mode, in which the keyboard and mouse remain locked but the operating system can start. You can unlock the keyboard and mouse by typing the power-on password.

If you forget the power-on password, you can regain access to the server in any of the following ways:

  • If an administrator password is set, type the administrator password at the password prompt. Start the Setup utility and reset the power-on password.
  • Remove the battery from the server and then reinstall it. See Removing the system battery for instructions for removing the battery.
  • Clear CMOS data by using the clear CMOS jumper (see System-board jumpers for more information).
    Attention
    Before you change any switch settings or move any jumpers, turn off the server; then, disconnect all power cords and external cables. See the safety information that begins in Safety. Do not change settings or move jumpers on any system-board switch or jumper blocks that are not shown in this document.

    Clearing CMOS data does not affect the administrator password.