Skip to main content

Removing a USB embedded hypervisor flash device

To remove a USB embedded hypervisor flash device, do the following:

  1. Turn off the server. Then, disconnect all external cables and remove all peripheral devices.
  2. Remove the server cover. See Removing the server cover.
  3. Remove the air baffle. See Removing the air baffle.
  4. Remove the PCI riser-card assembly. See Removing the PCI riser-card assembly.
  5. Locate the USB embedded hypervisor flash device connector on the system board. See System-board connectors.
  6. Slide the lock bar on the flash device connector to the unlocked position and pull the USB flash device out of the connector.
    Figure 1. USB embedded hypervisor flash device removal
    USB embedded hypervisor flash device removal

  7. Complete the parts replacement. See Completing the parts replacement.