Switch zoning for MSA2000 storage systems

Switch zoning configurations for the MSA2000 system include considerations for fabric zoning, target port sharing, host splitting, and controller splitting.

Fabric zoning

Each Lenovo Storage V7000 switch zone must include at least one target port from each controller to have no single point of failure. This means, for example, that the zone on the first fabric has Port 0 MSA Controller A with Port 1 of MSA Controller B and the Lenovo Storage V7000 ports. The zone on the second fabric has Port 0 MSA Controller B and Port 1 MSA Controller A and the Lenovo Storage V7000 ports. For more information about the Fibre Channel dual-fabric setup, see the relevant MSA documentation.

Target port sharing

Target ports may not be shared between Lenovo Storage V7000 and other hosts.

Host splitting

A single host must not be connected to Lenovo Storage V7000 and an MSA2000 system simultaneously.

Controller splitting

MSA2000 system LUNs must be mapped only to the Lenovo Storage V7000clustered system. The four target ports are all required for dual SAN-fabric connections and cannot be shared.