Sharing the EMC Symmetrix or Symmetrix DMX system between a host and the system

Follow these restrictions when you share EMC Symmetrix and Symmetrix DMX systems between a host and the system.

An EMC Symmetrix or Symmetrix DMX system can be shared between a host and the system under the following conditions:
  • When possible, avoid sharing target ports between the system and other hosts. If you cannot avoid this situation, you must regularly check the combined I/O workload that is generated by the system and the other hosts. The performance of either the system or of the hosts is affected if the workload exceeds the target port capabilities.
  • A single host must not be connected to both the system and an EMC Symmetrix or Symmetrix DMX because the multipathing drivers (for example, subsystem device driver (SDD) and PowerPath) cannot coexist.
  • If the EMC Symmetrix or Symmetrix DMX is configured in such a way that other hosts cannot access the LUs that are managed by the system, other hosts can be directly connected to an EMC Symmetrix or Symmetrix DMX system at the same time as a system.